New!年代tay informed with our freeemail newsletter.
advertisement
年代cience News
from research organizations

Infrared frequency comb measures biological signatures

Date:
June 7, 2019
年代ource:
National Institute of Standards and Technology (NIST)
年代ummary:
Researchers have demonstrated a compact frequency-comb apparatus that rapidly measures the entire infrared band of light to detect biological, chemical and physical properties of matter.
年代hare:
advertisement

FULL STORY

Researchers at the National Institute of Standards and Technology (NIST) and collaborators have demonstrated a compact frequency-comb apparatus that rapidly measures the entire infrared band of light to detect biological, chemical and physical properties of matter. Infrared light travels in waves longer than visible light and is most familiar as the radiation associated with heat.

The NIST setup, which occupies just a few square feet of table space, has potential applications such as disease diagnosis, identification of chemicals used in manufacturing, and biomass energy harvesting. The work is described in the June 7 issue of年代cience Advances.

Optical frequency combs measure exact frequencies, or colors, of light. Various comb designs have enabled the development of next-generation atomic clocks and show promise for environmental applications such as detecting methane leaks. Biological applications have been slower to develop, in part because it's been hard to directly generate and measure the relevant infrared light.

To showcase biological applications, the NIST team used the new apparatus to detect "fingerprints" of NIST's monoclonal antibody reference material, a protein made of more than 20,000 atoms that is used by the biopharmaceutical industry to ensure the quality of treatments.

"For the first time our frequency combs have simultaneous coverage across the entire infrared molecular fingerprint region," project leader Scott Diddams said. "Other key advantages are speed, resolution and dynamic range in acquiring data."

Mid-infrared light is an especially useful research probe because molecules usually rotate and vibrate at these frequencies. But until now it's been difficult to probe this region due to a lack of broadband or tunable light sources and efficient detectors such as those available for visible and near-infrared light, the part of the infrared spectrum closest to visible light.

新NIST装置克服了这些问题。年代imple fiber lasers generate light spanning the entire range used to identify molecules -- that is, mid-infrared to far-infrared wavelengths of 3-27 micrometers (frequencies of approximately 10-100 terahertz). The amounts of light absorbed at specific frequencies provide a unique signature of a molecule. The new system is innovative in detecting the electric fields of the absorbed light using photodiodes (light detectors) operating in the near-infrared range.

advertisement

"A unique feature is that we detect signals in real time by rapidly sampling the infrared electric field with a near-infrared laser," Diddams explained. "This has two advantages: It shifts the detection from the infrared to the near-infrared where we can use inexpensive telecommunications photodiodes, and we no longer suffer from the limitations of infrared detectors, which require cryogenic (liquid nitrogen) cooling."

The researchers detected signature vibrations of three bands of amides (chemical groups containing carbon, oxygen, nitrogen and hydrogen) in the monoclonal antibody reference material. Amide bands in proteins are used to determine the folding, unfolding and aggregating mechanisms. Specific features of the detected bands indicated that the protein has a sheet structure, agreeing with previous studies. Sheets connect chemical groups in a flat arrangement.

In addition to biological applications, the new apparatus might be used to detect interactions between infrared light and condensed matter for quantum computing approaches that store data in molecular vibrations or rotations. In addition, when combined with novel imaging techniques, the tabletop system could obtain nanometer-scale images of samples that currently require the use of a much larger synchrotron facility.

Coauthors of the new paper include researchers from the University of Campinas, in Brazil, and the Institute of Photonic Sciences, in Spain. Funding was provided by the Defense Advanced Research Projects Agency, the National Research Council and the Air Force Office of Scientific Research.


年代tory Source:

Materials provided byNational Institute of Standards and Technology (NIST).注意:内容可能被编辑风格d length.


Journal Reference:

  1. A.S. Kowligy, H. Timmers, A. Lind, U. Elu, F.C. Cruz, P.G. Schunemann, J. Biegert and S.A. Diddams.Infrared electric field sampled frequency comb spectroscopy.年代cience Advances, 2019 DOI:10.1126/sciadv.aaw8794

Cite This Page:

National Institute of Standards and Technology (NIST). "Infrared frequency comb measures biological signatures." ScienceDaily. ScienceDaily, 7 June 2019. /releases/2019/06/190607140439.htm>.
National Institute of Standards and Technology (NIST). (2019, June 7). Infrared frequency comb measures biological signatures.年代cienceDaily. Retrieved October 27, 2023 from www.koonmotors.com/releases/2019/06/190607140439.htm
National Institute of Standards and Technology (NIST). "Infrared frequency comb measures biological signatures." ScienceDaily. www.koonmotors.com/releases/2019/06/190607140439.htm (accessed October 27, 2023).

Explore More
from ScienceDaily

RELATED STORIES